  elite series elite series elite series elite series DS-ELITE-1 applications ? garden lighting ? pond pumps ? remote outdoor switching ? access control ? industrial control features ? 4 switched channels 1000w rated ? systems with 250m or 1000m range ? 230vac supply ? completely waterproof abs enclosure (ip68) ? all outputs momentary, latching or timed ? any switch maps to any switch or multiple switches ? systems supplied ready to go ? 868mhz reliable fm technology ? emc compliant for europe ? 10 cable entry points for easy installation. description whatever your switching application the elite remote control system with 4 individual 230v outputs and its completely waterproof ip68 enclosure will be a great choice. the elite remote control system has been designed with the requirements of electricians in mind and therefore it can be used to switch all lighting types as well as other applications such a s water features, electric gates and garage doors. each receiver has 4 switched outputs. using our one touch easy-learn proc- ess each relay can be controlled from any switch on any compatible transmit- ter. thanks to the latest technology each of the 4 outpu ts on the elite remote control system can be set to operate in a timed, momentary or latc hing mode allowing for complete flexibility. professional remote control systems professional remote control systems professional remote control systems professional remote control systems
elite remote control system elite remote control system elite remote control system elite remote control system DS-ELITE-1 page 2 system part numbering part number description elite-xt1 transmitter 1 switch elite-xt2 transmitter 2 switch elite-xt4 transmitter 4 switch firefly-tx-ipkit o ring, seals transmitter to ip68 elite-xt6 transmitter 4 switch + all on/off elite-xt16 transmitter 16 switch (8sw + shift key) elite-xt8 transmitter 8 switch part number description receiver power supply range** (metres) elite-s4 system 4 outputs 230vac 250 elite-rx receiver 4 output 230vac - elite-xs4 system 4 outputs 230vac 1000m additional transmitters part number description elite-t6 transmitter 4 switch + all on/off elite-x series 2000m range transmitters elite series 250m range transmitters transmitters ship with: wall mounting cradle and lanyard ** range stated is optimumline of sight transmitter dimensions and details on page 7 transmitter dimensions and details on page 7
elite remote control system elite remote control system elite remote control system elite remote control system DS-ELITE-1 page 3
elite remote control system elite remote control system elite remote control system elite remote control system DS-ELITE-1 page 4 quick installation guide (systems only) the elite system provides 4 switches each capable o f switching up to 1kw (4a @ 230v). each channel is inde- pendent and separately fused. the elite remote cont rol system provides 230v mains switched outputs via each terminal. 1. first mount the elite system receiver box in the wall in your desired location (see page 7 for wall mounting dimensions and information). 2. open the enclosure by removing fixing screws fro m the enclosure front and then removing the front from the enclosure. 3. wire the live neutral and earth connections to t he power supply screw terminal as shown below (shown as a). 4. wire your load(s) as required (shown as b) 5. once all required wiring is complete, use the ha ndheld elite transmitter to switch the outputs on a nd off. 6. as supplied the handheld will operate the output s - button 1 to output 1, button 2 to output 2 etc. 7. all buttons will operate in a latching mode - pr ess for on, press again for off. it is possible to change the operation to momentary mode by fitting the links (shown as c) 8. for advanced operation such as adding extra tran smitters different button mapping options see ad- vanced operation section. fig 1.1 fig 1.1 fig 1.1 fig 1.1
elite remote control system elite remote control system elite remote control system elite remote control system DS-ELITE-1 page 5 advanced operation the elite system comes with one transmitter, this i s already synced and will operate the system out of the box. to auto-snyc a new transmitter 1. to sync a new elite handheld transmitter to the receiver box - simply press the snyc button on the elite receiver board. (see page 3 for button locati ons) 2. the elite receiver will flash all of its relay output leds at a high rate to show that it is ready for auto-sync. 3. press any button on the transmitter handheld tha t you wish to snyc to the receiver. 4. all flashing leds will go out, led 8 will flash quickly for 2 seconds then go out. 5. the elite receiver will then exit sync mode and return to normal operating mode - you may now use the transmitter to switch the outputs. manual-sync individual transmitter buttons (advance d) 1. to sync a specific elite handheld transmitter bu tton to a specific output on the elite receiver box - press the snyc button on the elite receiver board. (see page 3 for button locations). 2. the elite receiver will flash all its relay out put leds at a high rate to show that it is ready fo r sync. 3. press the sync button again - the elite receiver will flash output led 1 only - this is showing tha t out- put 1 is selected. pressing the sync button again w ill select output 2 and so on to output 4. 4. once you have selected the required output (that output led only is flashing) press any button on t he transmitter handheld that you wish to snyc to the r eceiver. 5. the flashing leds will go out, led 8 will flash quickly for 2 seconds then go out. note: after a successful pairing the elite-rx will exit s ync mode automatically. you cannot sync all and manual sync a single trans mitter. erasing all transmitters: 1. open the case and apply power 2. press and hold the erase button for 10 seconds 3. all relay leds flash together and then go out 4. erase complete, you can now follow the pairing p rocess to pair your transmitters to the receiver. erase individual transmitters: 1. open the case and apply power 2. press and release the erase button 3. the led next to erase should remain lit and all relay leds will be flashing 4. press any button on the transmitter to be erased 5. all output leds will go out to show that the tra nsmitter has been erased 6. the elite will exit to normal operating mode erasing all timers: 1. open the case and apply power 2. press and hold the timer button for 10 seconds, 3. a single relay led will be flashing 4. when all relay led flash together and then go ou t the timer erase process is complete. 5. all relays will operate as per their jumper sett ings.
elite remote control system elite remote control system elite remote control system elite remote control system DS-ELITE-1 page 6 advanced operation continued i nstallation test mode the elite comes with an in-built test mode which al lows a user to check the signal strength of any compatible handheld: 1. press the signal test button on the pcb 2. press any button/activate the transmitter which you want to test 3. leds 1-8 will show a bar graph of the signal str ength - the more leds on the better the signal tip: try the transmitter in the location where it will b e used to make sure it will work once installation is com- plete. note : when in test mode and paired transmitter will sti ll activate its relay. for reliable communications please ensure at leas t 3 leds are lit. installation timer select mode note: as default all timers are set to 0 seconds. the elite has a timer option which can be set indiv idually on each output. meaning that you can set an y out- put to de-activate after a different amount of time should you wish 1. to enter timer select mode - press the timer sel ect button 2. select your chosen output by pressing the timer select button to scroll through each relay in turn 3. when the led for the required output is flashing wait until it becomes solidly lit 4. press the timer select button again to increase the timer delay in line with the table belo 5. when you have selected the required delay, wait 3 seconds. all red leds will flash to show that the set- ting is saved note: settings are saved even after power is remove d. when zero leds are lit the relays will operate a s per the jumper links. momentary or latching. setting momentary / latching links note: as default all relay switches are latching. it is possible to set the relay switches on the eli te receiver to either momentary or latching operati on (latching - one press for on, one press for off, mo mentary - on while button is held only) 1. remove all power from the receiver and then open the elite-rx receiver enclosure. unscrew the an- tenna and slide out the pcb. 2. the momentary/latching setting links are in the position shown as (c) page 4. 3. to set a relay switch to momentary, simply set t he links as per the below table for the appropriate relay switch. 4. re-assemble the elite-rx and re-apply the power. 0 led 1 led 2 led 3 led 4 led 5 led 6 led 7 led 8 led 0s ? s 5s 10s 30s 1m 10m 30m 1hr
elite remote control system elite remote control system elite remote control system elite remote control system DS-ELITE-1 page 7 technical specifications transmitters: elite-tn enclosure rating: not waterproofed battery type: cr2032 (supplied) battery life: 3 years @ approx 50 1/2second presse s p/day dimensions: 86 x 54 x 7 mm changing the battery: carefully squeeze in the battery lock tab on the ba se of the transmitter, and then pull out the battery tray transmitters: elite-xn enclosure rating: standard ipx8 battery type: 3 x aaa (supplied) battery life: 5 years @ approx. 50 1/2second press es p/day dimensions: 90 x 54 x 27 mm changing the battery: remove the six fixing screws. remove 2 battery comp artment screws and replace batter- ies, taking care of cables and battery polarity receiver decoder: elite-rx enclosure rating: ip68 dimensions: 267 x 148 x 78 mm (not including ante nna) storage temperature: -10 to +70 o celsius. operating temperature: -10 to +50 o celsius. *the relay contacts in this unit are for functional use only and must not be used for isolation purpos es approvals information: ? all rf solutions products are manufactured in accor dance with our iso:9001 quality system ? elite systems are manufactured to ce standards ? further information available on request. electrical characteristics min typical max units supply voltage 3v v frequency: 869.500 mhz rf output power (erp) @ 868 mhz - 3 mw electrical characteristics min typical max units supply voltage 4.5v v frequency: 869.500 mhz rf output power (erp) @ 868 mhz - 50 100mw mw electrical characteristics min typical max dimension supply voltage for +230 vac 230vac vdc relay rating* (230vac) rly1-4 5rms 12peak a supply current : quiescent all relays operating* 40 140 ma time delay from tx on switch to rx relay operation 30 ms time delay from tx sw relax to rx relay release 30 ms
elite remote control system elite remote control system elite remote control system elite remote control system information contained in this document is believed to be accurate, however no representation or warran ty is given and r.f. solutions ltd. assumes no liability with respect to the accuracy o f such information. use of r.f.solutions as critica l components in life support systems is not authorised except with express written approval from r.f.solutions ltd. rf solutions ltd. recycling notice meets the following ec directives: do not discard with normal waste, please recycle. rohs directive 2002/95/ec specifies certain limits for hazardous substances. weee directive 2002/96/ec waste electrical & electronic equipment. this produ ct must be disposed of through a licensed weee collection poin t. rf solu- tions ltd., fulfills its weee obligations by member ship of an approved compliance scheme. wall mounting template (not to scale) waste batteries and accumulators directive 2006/66/ec where batteries are fitted, before recycling the product, the batteries must be removed and disposed of at a licensed collection point. environment agency producer registration num- ber: wee/jb0104wv.


▲Up To Search▲   

 
Price & Availability of DS-ELITE-1

All Rights Reserved © IC-ON-LINE 2003 - 2022  

[Add Bookmark] [Contact Us] [Link exchange] [Privacy policy]
Mirror Sites :  [www.datasheet.hk]   [www.maxim4u.com]  [www.ic-on-line.cn] [www.ic-on-line.com] [www.ic-on-line.net] [www.alldatasheet.com.cn] [www.gdcy.com]  [www.gdcy.net]


 . . . . .
  We use cookies to deliver the best possible web experience and assist with our advertising efforts. By continuing to use this site, you consent to the use of cookies. For more information on cookies, please take a look at our Privacy Policy. X